- Exhaust AutoPlus5 Gas Diagnostics brochure_-_Spanish
- AutoPlus5 Exhaust_Gas_Diagnostics_brochure at ANSED
- The_CATalytic_Convertor sold at ANSED version2.23
- Catalytic Converter and Exhaust System
- Drivability Diagnosis Yikes No Codes by_Bob_Freudenberger
- Getting the most out of the Exhaust Gas Analyzer
- Getting_the_Most_Out_of_Exhaust_Gas_Analyzers article
Automotive Exhaust Gas Diagnostic Kit w/ Printer
It is important that you register your new ANSED products within 30 days after purchase in order to activate the warranty. Fill in the form
California residents: Proposition 65 Information This product may contain chemicals, including lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. Read more
- ANSED/AUTOplus5/PR has superseded to ANSED/KANE-EGA5/PR
- Technical Specifications
- ANSED Exhaust Gas Diagnostic Software
- KANE LIVE Graphing Software
- What is in the ANSED/AUTOplus5/PR Diagnostic Kit?
The process of diagnosing general performance, drivability, no code and catalytic converter issues can be complex and frustrating. Modern OBDII systems may miss problems too small or infrequent to set a code. In seconds, the Autoplus 5 Exhaust Gas Analyzer will detect problems too marginal to be detected by an onboard computer or a scan tool.
Experienced technicians agree that an Automotive Exhaust Gas Analyzer is an integral part of their diagnostic toolbox. One quick test of the exhaust gases emitted from the tailpipe helps reduce diagnostic time, verify repairs are complete, reduce comebacks, and increase overall profitability and customer satisfaction.
With the ANSED Automotive Exhaust Gas Diagnostics System, there are no more charts and graphs, no more black magic calculations. The ANSED Exhaust Gas Diagnostics Software interprets the exhaust gases and their interactions and provides a top-down list of suggested problems and solutions in order of probability.
And, the KANE LIVE Graphing Software allows LIVE detailed monitoring of the gas readings on your PC.
The ANSED Exhaust Gas Diagnostics System is the most complete and comprehensive solution on the market today.
The KANE Gas Analyzer:
- Tests HC, O2, CO, CO2, NOX and Lambda
- All readings LIVE, not calculated
- Self-calibrating, no cal-gas required
- Dyno not required for NOx testing
Key Benefits:
- Completely portable
- Easy to hold in hand
- Sample exhaust gas in the shop or on a road test
- NOx testing without a dynometer
- Low cost to operate and maintain
- Operates off internal re-chargeable battery
- Self-calibrating, no cal-gas required.
- Water trap and filter visible
- Fast diagnostic times
- All readings LIVE “real-time”, not calculated
Key Features:
- QVGA Display
- Large (3 x 2.2”) and easy to read all gases and Lambda on one screen, no scrolling
- Ergonomic Design Keypad
- Simple and easy to navigate and use
- Bluetooth or USB Cable ready
- Links analyzer easily to PC to use with KANE LIVE Graphing Software
- Variable Pump Speed
- Allows for adjustment of the pump speed, which can then improve battery life
- Hi-Speed Print Capability
- Use with the KMIRP2 hi-speed printer with rechargeable battery
- Probe
- Equipped with the EPAUTO7 Hi-Temperature Probe, with Neoprene tubing.
Parameter |
Resolution |
Accuracy |
Range |
Carbon Monoxide (Infrared) |
0.01 % |
+/- 5 % of reading *1 +/- 0.06 % volume *1 |
0-10 % Over-range 20 % |
Oxygen (fuel cell) |
0.01 % |
+/- 5 % of reading*1 +/- 0.1 % volume *1 |
0-21 % Over-range 25 % |
Hydrocarbon (Infrared) |
1 ppm |
+/- 5 % of reading *1 +/- 12 ppm volume *1 |
0-5000 ppm Over-range: 10,000 ppm |
Carbon Dioxide (Infrared)) |
0.1 % |
+/- 5 % of reading *1 +/- 0.5 % volume *1 |
0-16 % Over-range: 25% |
Nitric Oxide*² (fuel cell) |
1 ppm |
0-1500ppm +/-5% or 25ppm; |
0-1500ppm Over-range: 5000 ppm |
Carbon Monoxide Corrected COK |
0.01% |
Calculated |
0-15% |
Lambda AFR (Petrol) (LPG) |
0.001 00.01 |
|
0.8 – 1.2 11.76 – 17.64 12.48 – 18.72 |
Sensor response T95 |
Nominal 20 seconds AUTOplus5 |
Warm up |
Less than 2 minutes |
Pre-programmed Fuels |
Petrol/Gasoline, LPG Diesel and CNG. |
PC connection |
Via RS 232 port |
Data-Logging |
500 Tests |
Dimensions Weight Handset Probe |
1kg (2.2 pounds) 220mm x 55mm x 120mm (8.7 x 2.2 x 4.7”) Insertion depth 350mm x Diameter 15mm Clip handle to secure to exhaust, 4m long hose Various probes available including high temperature |
Ambient Operating Range |
+5°C to +45°C/10% to 90% RH noncondensing |
Storage temperature |
Minimum: 0°C Maximum: +50°C |
Battery Charger |
Input: 100-240 V ~ 47-63 Hz Output: 12 V DC |
Analyzer battery run time |
4+ hours from full charge with the pump running, 8+ hours with pump off. To charge, 6-8 hours. |
The ANSED Exhaust Gas Diagnostics software interprets the exhaust gas analyzer readings in seconds!
The software uses a floating matrix formula for each gas reading, coupled with other diagnostic variables, to enhance the accuracy. Several possible solutions, in order of probability, are suggested with the first one the likely cause in 80% of the situations.
- Effective interpretation of exhaust gas readings
- Offers problem identification and potential solutions
- Diagnose no-code drivability & performance issues
- Ensure catalytic converter related repairs are complete
- Print test results reports: pre- and post-repair
- Verify vehicle running at max efficiency after repairs and prevent comebacks
Key Benefits:
- Instant exhaust gas analysis with an easy-to-read PASS/FAIL report.
- Provides a top-down list of probable causes and suggested service options.
- Pre-repair reports provide initial gas analysis for review.
- Customer Report offers a “customer friendly analysis” of the exhaust diagnostic test.
- Technician Report details the diagnostic test results and suggested procedures. - Post-repair report verifies that repairs have been completed and the vehicle is running at maximum efficiency.
- All reports can be printed or saved for future reference.
The KANE LIVE Graphing Software is a great way to connect to the AUTOplus5 Gas Analyzer to view gas exhaust readings, all in "real-time” on your PC via Bluetooth™ or USB Cable.
Data is viewed either digitally or in graph form so you can easily track parameters over time as they change.
If required, the live data can be saved and stored on your PC. The software also allows for printing.
Key Benefits:
- Monitor individual exhaust gas readings digitally on a larger PC screen.
- Graphically display individual gas readings over time.
- Check individual exhaust gas readings for dropouts, spikes or irregularities in graphing mode.
- Save all information to PC for future reference.
- KANE AUTOplus5 Gas Analyzer
- EPAUTO7 Hi-Temp Probe
- KMIRP2 Hi-Speed Printer
- AC Charger
- 12V DC Charger
- Five (5) Replacement Filters
- User Manual & Quick Start Guide
- ANSED Exhaust Gas Diagnostics Software (FREE)
- KANE Live Graphing Software (FREE)
- CL5 USB Cable
- Shoulder Bag
- Exhaust AutoPlus5 Gas Diagnostics brochure_-_Spanish
- AutoPlus5 Exhaust_Gas_Diagnostics_brochure at ANSED
- The_CATalytic_Convertor sold at ANSED version2.23
- Catalytic Converter and Exhaust System
- Drivability Diagnosis Yikes No Codes by_Bob_Freudenberger
- Getting the most out of the Exhaust Gas Analyzer
- Getting_the_Most_Out_of_Exhaust_Gas_Analyzers article